7 Drive Machine Data (SIMODRIVE Drive MD)

12.93

7.1.2 MSD MD (data description - SW 3)

Switchover speed current controller adaptation motor 1

120

Default value

Lower input limit

Upper input limit

Units

MD 172

500

10 000

rev/min

Active

at once

Input of switchover speed for the current controller adaptation. The phase current controller
gain is adapted as a function of speed. The specified speed is the speed at which the phase
current controllers reach their maximum gain.

4 x gain set
in MD 116

Phase current
controller gain

MD 120

n

MD 116

MD 337

Module identifier

150

Default value

Lower output limit

Upper output limit

Units

Hex

Active

at once

Display machine data for module identifier.

Value table:

0H

Measuring circuit for incremental encoder with
sinusoidal voltage signals

1H

Measuring circuit for incremental encoder with
sinusoidal current signals

FH Not fitted

Bit 4-7

Not assigned

Bit 8-11

0H

Measuring circuit for incremental encoder with
sinusoidal voltage signals

1H

Measuring circuit for incremental encoder with
sinusoidal current signals

FH Not fitted

Bit 12-15

Not fitted

Spindle
measuring
circuit

Motor
measuring
circuit

Bit 0-3

Bit 8-11

Not assigned

Measuring circuit

7–18

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50