09.95

Siemens AG 2001

All Rights Reserved

6FC5197–

j

AA50

9–45

SINUMERIK 840C (IA)

II

Counter 2

Counter 1

I

III

IV

Quadrant transition point

Fig. 9.20

Radius deviations at the quadrant transition points without compensation

Setting the compensa-

If the compensating amplitude is too small, the circularity test shows that the

ting amplitude

radius deviations from the programmed radius at the quadrant crossover points
have insufficient compensation (see Fig. 9.21).

II

Counter 2

Counter 1

I

III

IV

Fig. 9.21

Radius deviations at the quadrant crossover points with insufficient compensa-

tion

If the compensating amplitude is too high, the circularity test clearly shows the
overcompensation of the radius deviations at the quadrant crossover points (see
Fig. 9.22).

9 Drive Servo Start-Up Application (as from SW 3)

9.5.3 Conventional quadrant error compensation (as from SW 2)