7 Drive Machine Data (SIMODRIVE Drive MD)

10.94

7.4.3 Diagnosis/service MD (data description - as from SW 3)

Bit 2 - SW 4

Bit 3 - SW 3

Bit 3 - SW 4

Bit 4 - SW 3

Bit 4 - SW 4

Bit 5 - SW 3

Bit 5 - SW 4

Bit 6 - SW 4

I n

act

I < n

min

Programmable message 4

I n

act

I < n

x

Programmable message 5

n

soll

= n

ist

Programmable message 6

Variable message function

(n

set

- n

act

) < DELTA (–)

0 : off
1 : on

Bit 7 - SW 4

Bit 8 - SW 4

Bit 9 - SW 4

(n

set

- n

act

) > DELTA (+)

Actuating voltage U

stell(q)

> U

max

Current setpoint I

set

> I

max

0 : off
1 : on

Bit 10

Assigned to or reserved for system-internal functions

Bit 11 - SW 4

Bit 12 - SW 4

Bit 13 - SW 4

Set speed n

set

> n

Uewa-Motor

Actuating voltage U

stell(d)

> U

max

Torque setpoint m

set

>m

limit

0 : off
1 : on

Bits 14-15

Assigned to or reserved for system-internal functions

Drive status

11008

Default value

Lower output limit

Upper output limit

Units

0

5

Active

at once

This machine data defines the ramp-up and operating status of the digital drives on an axis-
specific basis. The status is generated during ramp-up in the SERVO and updated accordingly
when the machine data is accessed.

Bit 0

Drive off

Bit 1

Drive on (after establishment of drive link)

Bit 2

On-line (communications connection between NC and drive)

Bit 3

Bootstrapping (drive must be booted)

Bit 4

Connected in (drive has ramped up to setpoint)

Bit 5

Ready (drive in control circuit, power connected) ˆ

= MD 11003.5

7–174

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

SINUMERIK 840C (IA)