6 NC Machine Data (NC MD), NC Setting Data (NC SD)

09.95

6.7 Axis-specific MD 2 (axial data 2)

Motor current on equilibration (as from SW 3)

1292*

Default value

Lower input limit

Upper input limit

Units

0

-70

-700 (as from SW 4)

70

700 (as from SW 4)

0.1 % of the

power section

current

Active on

NC Stop

MD 1292* is used to define the value of an additional torque of a motor used to compensate
for stationary loads (e.g. pull of gravity on hanging axes) (this MD is only active for digital feed
spindle drives).

Note: As from SW 4, for 8 parameter sets

Period of the learning signal (as from SW 4.4)

1296*

Default value

Lower input limit

Upper input limit

Units

0

0

16 000

ms

Active on

NC Stop

The learning signal period of neural quadrant error compensation can be changed with this
data. This also alters the required traversing range and the learning time.

Note:

With default value 0 and values under 500 ms are used a permanently set period length of 2 s
is used. Up to SW 4.3 this time cannot be parameterized and is permanently set to 1 s.

Basic distance for distance coding

1300*

Default value

Lower input limit

Upper input limit

Units

1 000

0

16 000

Active on

Power On

Active:

After POWER ON

The basic distance between the reference marks for distance coded linear scales entered in
multiples of the grating pitch (division period).

External pulse multiplication

1304*

Default value

Lower input limit

Upper input limit

Units

1

1

100

Active on

Power On

Active:

After Power On

External pulse multiplication factor (e.g. external EXE error) for linear measuring systems with
distance coded reference points.

The number of signal periods (grid lines) that are generated from one division period of the of
the linear scale (grating pitch) by external interpolation digital electronics.

Servo gain factor 4th parameter set (as from SW 4)

1308*

Default value

Lower input limit

Upper input limit

Units

1 666

0

10 000

80 000 (as from SW 5)

0.01s

-1

Active on
NC Stop

These MD have the same meaning as MD 252*, see also ”Functional Descriptions: Parameter
set switchover”.