Siemens SINUMERIK 840C User Manual

Page 272

Advertising
background image

08.96

6 NC Machine Data (NC MD), NC Setting Data (NC SD)

6.6.1 General MD bits (general bits)

Auxiliary

function

output
before

travel

No de-

celeration

at limit

switch

Working

area

limitation

in force in

JOG mode

Interpol.

params

dependent

on

G91/G90

Internal

WAIT mark

synchroni-

zation (as

from SW

5.6)

No NC

STOP in

dwell block
G04S.../G1

4/G24 (as

from SW

5.4)

7

6

5

4

3

2

1

0

Bit No.

NC MD

5003

Polar

coord.

angle de-

pendent

on

G91/G90

Do not clear

PRESET

OFFSET on

POWER

ON

Default value:

0000 0100

Bit 7

No deceleration on reaching the software limit switch. When this bit is set, braking
does not follow the acceleration/deceleration curve; only the following error is
suppressed. The limit switch is not overrun to any great extent (also see NC MD
1100*).

Active:

NC Stop

Note

In the case of interpolating axes, all axes are stopped when the range limit of an
axis is reached. Stopping without a contour violation, however, is guaranteed only
when bit 7 of MD 5003 is not set (no deceleration at limit switch), i.e. deceleration
takes place over the acceleration ramp.

Speed specified by interpolator

Actual axis speed

Bit 7=0

V

t

Bit 7=1

V

t

Bit 6

The working area limitation is also effective in JOG mode. In addition to the
software limit switches, the working area can therefore be limited in JOG mode,
thereby better safeguarding the machine against unintentional travel. However,
since a working area limitation is a software limitation, proper operation can only be
ensured following reference point approach.

Active:

NC Stop

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

6–87

SINUMERIK 840C (IA)

Advertising
This manual is related to the following products: