04.96

7 Drive Machine Data (SIMODRIVE Drive MD)

7.3.2 Drive MD (data description)

•

Diagnostic function "Voltage-controlled V

q

operation" (up to SW 4)

A voltage-controlled operating mode (V/F mode) is applied in order to diagnose speed or
current sensor faults. In this operating mode, voltages V

q

and V

d

= 0 as well as a

frequency are input as controlled quantities. As a result of the transformation (d/q
R/S/T), a constantly changing rotating field is applied to the motor via the trigger
equipment ASIC, making it possible to attain a speed within the n

rated

/5 range in V/F

operation. The system oscillates at higher speeds.

Corresponding machine data are as follows:

–

Motor frequency V/F mode (MD 1660)

–

Ratio V/F during V/F mode (MD 1661)

•

If MD 1661 is set to an excessively high value, the resulting I

d

current at n

rated

/5 causes a

temperature rise in the drive and an additional increase in oscillation at high speeds.

•

If MD 1661 is set to a very low value, the resulting I

q

current value is too low, making it

impossible for the drive to follow the specified frequency.

•

An operating status message is transmitted to the SERVO by means of bit 28 in the status
word.

•

The current and speed controllers are not active in V/F mode

•

Unfavourable parameter settings may cause excessively high currents to occur in V/F
mode; the existing current monitoring function therefore remains active.

Signal number min/max memory

1651

Default value

Lower input limit

Upper input limit

Units

0

0

100

–

Active

at once

Input of signal number of memory location to be monitored by the min/max memory function.

Caution:

This machine data is relevant only for Siemens-internal purposes and must not be altered.

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

7–149

SINUMERIK 840C (IA)