09.95

7 Drive Machine Data (SIMODRIVE Drive MD)

7.2.2 FDD MD (data description - SW 3)

Note:

This machine data is calculated only once during ramp-up; its value cannot therefore be
changed during operation.

CRC diagnosis parameter

1720

Default value

Lower output limit

Upper output limit

Units

0000

0

FFFF

Hex

Active

at once

This machine data is used to display detected CRC errors (cyclical redundancy check). The
counter information is output with every read request and is 5 bits in width (bit 4...bit 0 or
counter reading 0...31).

Note:

It cannot be guaranteed in all cases that the CRC error is assigned to the appropriate drive.
When the address is faulty, the "wrong" module indicates the error.

Data version

1797

Default value

Lower output limit

Upper output limit

Units

0

0

32 767

Active

at once

Output of current data version (machine data list).

Firmware date

1798

Default value

Lower output limit

Upper output limit

Units

0

0

32 767

Active

at once

Output of coded software version in decimal format. The date is coded as such: DDMMY,
where DD stands for day, MM for month and Y for the last number in the year.

Example: 01.06.1993 ˆ

= 01063

dec

Firmware version

1799

Default value

Lower output limit

Upper output limit

Units

0

0

32 767

Active

at once

Output of current software version (configuration management).

©