8 PLC Machine Data (PLC MD)

09.95

8.2 PLC MD for the operating system (system data)

Byte no. of 2nd alarm byte

125

Default value

Lower input limit

Upper input limit

Units

- 1

- 1

127 (SW 4 and

higher)

DB 60

DW 125

Byte no. of 1st alarm byte

124

DB 60

DW 124

Byte no. of 3rd alarm byte

126

DB 60

DW 126

Byte no. of 4th alarm byte

127

DB 60

DW 127

This PLC MD can be used to define as many as 4 input bytes as alarm bytes. The PLC
software scans these bytes for changes every 10 ms. Enter - 1 for input bytes that are not to
serve as alarm bytes.

The PLC outputs an error message and goes to STOP if illegal values are detected on a cold
restart.

If enabled in PLC MD 6050, bit 3 (bit 3 = 0), OB 3 is invoked when an alarm is generated.

Address 1st machine control panel

128

Default value

Lower input limit

Upper input limit

Units

64

0

127 (SW 4 and

higher)

DB 60

DW 128

Address 2nd machine control panel

129

Default value

Lower input limit

Upper input limit

Units

72

0

127 (SW 4 and

higher)

DB 60

DW 129

These PLC MD specify the start address (byte) for the machine control panels.

Eight bytes are required for each control panel. The inputs and outputs for each control panel
have the same address numbers.

8–10

© Siemens AG 1992 All Rights Reserved 6FC5197- AA50