04.96

12 Functional Descriptions

12.28.8 Overview of function identifiers and configuring parameters (DB 2, DR 2 ... DR 6)

Example:

Parameterization of DB 2 for reading without acknowledgement of the signal path feedrate
(signal No. = 2) in the 3rd channel is as follows:

Byte no.

Content

Meaning

DL 0

0x01

Operation without acknowledgement/reading/set strobe

DR 0

--

Error code from NC (output parameter)

DL 1

0x13

Job number of PLC

DR 1

0x01

No. of the data transfer area

DL 2

0x10

Refresh rate NC

DR 2

0x03

Function ID of the service function

DL 3

0x00

Configuration parameter 1 LOW

DR 3

0x00

Configuration parameter 1 HIGH

DL 4

0x02

Configuration parameter 2 LOW = Signal No.

DR 4

0x00

Configuration parameter 2 HIGH = Signal No.

DL 5

0x00

Configuration parameter 3 LOW = Axis No.

DR 5

0x00

Configuration parameter 3 HIGH = Axis No.

DL 6

0x03

Configuration parameter 4 LOW = Channel/IKA No.

DR 6

0x00

Configuration parameter 4 HIGH = Channel/IKA No.

Writing these signals from the PLC is not permitted. If an attempt is made to perform a write
access, the error code 41 "Configuration parameter 2 incorrect" is indicated in DB 2 DR 0.

Examples for "Servo Trace" or high-speed data channel

The following abbreviations are used:

MW = Measured value, i.e. the measured value that can be read off in the trace curve or the
data transfer range of the "high-speed data channel" received on the PLC side.

RW = Real value, i.e. the measured value converted into the physical quantity. Usually, this
physical quantity has the same unit as in the part program, e.g. mm/min for the feedrate. This
unit is indicated in square brackets.

IT=Interpolation cycle [ms]

EF=Input resolution, corresponds to MD 5002.4-7

LF=Position controller resolution, corresponds to MD 18000.0-3

© Siemens AG 1992 All Rights Reserved 6FC5197- AA50