Siemens SINUMERIK 840C User Manual

Page 663

Advertising
background image

Display

09.95

Siemens AG 2001

All Rights Reserved

6FC5197–

j

AA50

9–42

SINUMERIK 840C (IA)

Explanation

The following service data are output cyclically in the above display:

S

The following service data are output cyclically in the above display:

S

The axial acceleration at the instant of the last speed zero crossing

S

The compensation amplitude on the last speed zero crossing

S

The axis quadrant error (error criterion) of the neuronal QEC in cases where
an error measuring time is parameterized (see section “Further optimization
and intervention options”).

Note

The characteristic for the quadrant error compensation function in use to date
can be determined directly on the basis of the quantities acceleration and com-
pensation amplitude. Using the quadrant error (error criterion) as a basis, the set-
ting can be assessed (this value should be as low as possible).

SW 4
You can call the graphic representation of the circularity test by means of this
softkey.

Fig. 9.18

Explanation

This display shows the measured characteristic of the two axis position actual
values in the form of a circle with the resolution selected by the user. The mean
radius (or the programmed radius), the programmed feedrate and the circle mea-
surement time derived from these values are then displayed for documentation
purposes (i.e. for subsequent storage of the measured circle characteristic as a
file).

In order to accentuate the transitions on the quadrants, for example, the user can
set a finer scale for the diagram axes in the input field/selection with position
frame to the right. Softkey Display must then be selected again in order to dis-
play the entire circle diagram with the new resolution setting.

9 Drive Servo Start-Up Application (as from SW 3)

9.5.2 Circularity test (option – SW 4)

Advertising
This manual is related to the following products: