Siemens SINUMERIK 840C User Manual

Page 126

Advertising
background image

SAVE

Programm.

EDIT

NC

SELECT

PROGRAM

SAVE

START

OK

09.95

Siemens AG 2001

All Rights Reserved

6FC5197–

j

AA50

4–63

SINUMERIK 840C (IA)

You can create the PCF file with the ASCII editor, configuring is described in In-
terface Description Part 1. The ASCII editor is described in the Operator’s Guide.

You store the file onto the hard disk with the SAVE softkey.

Creating and editing PCF files in the programming area (NCK area)

Press the area switchover key.

Press programming key.

Press the edit NC softkey.

Enter the required program with the identifier “%PCF...” in the input line and ac-
cept with the PROGRAMMING softkey.

The DIN editor is displayed. Please refer to the Interface Description Part 1, Si-
gnals, for notes on configuring. The DIN editor is described in the Operator’s
Guide.

When you have completed editing, you must load the crea-
ted PCF file from the NCK memory in the DIAGNOSIS area
to the hard disk, as data are lost when the control is
switche doff.

Saving the PCF file

Enter passwords in the NCK and MMC area.

Select the DIAGNOSIS/START-UP/PLC DATA area with the cursor and the input
key and keep pressing the keys until you reach the directory of language files,
select and accept the required language.

Press the SAVE softkey. A dialog screen form with a toggle field and 4 input
fields appears.

You select the PCF data type with the horizontal cursor keys in the PLC
SOURCE toggle field. The input fields are filled in according to the entries in the
NCK memory.

You initiate transmission with the START softkey. The following message ap-
pears:

!!! Transmission from NC to PC active !!!

If a PCF file of the same name already exists you are asked whether you wish to
overwrite it:

PC data exists. Overwrite?

The PC data are overwritten when you press the softkey OK.

4 MMC Area Diagnosis

4.8.3 PCF files (up to SW 2)

Advertising
This manual is related to the following products: