7 Drive Machine Data (SIMODRIVE Drive MD)

04.96

7.2.2 FDD MD (data description - SW 3)

Note:

Current setpoint filter 1 is preset to the current controller sampling time MD 1000 =
125

µ

s for damping of the encoder torsional natural frequency.

Natural frequency current setpoint filter 2

1204

Default value

Lower input limit

Upper input limit

Units

0

0

8 000

Hz

Active

at once

Input of natural frequency for current setpoint filter 2 (PT2 low-pass). An entry of < 10 Hz as
the natural frequency of the low-pass filter initializes the filter as a proportional element with a
gain of 1 independently of the associated damping. The filter is activated via machine data MD
1200 and MD 1201.

Damping current setpoint filter 2

1205

Default value

Lower input limit

Upper input limit

Units

1.0

0.05

5

Active

at once

Input of damping for current setpoint filter 2 (PT2 low-pass). The filter is activated via machine
data MD 1200 (selection current setpoint filter) and MD (type current setpoint filter) 1201.

Natural frequency current setpoint filter 3

1206

Default value

Lower input limit

Upper input limit

Units

0

0

8 000

Hz

Active

at once

Input of natural frequency for current setpoint filter 3 (PT2 low-pass). An entry of < 10 Hz as
the natural frequency of the low-pass filter initializes the filter as a proportional element with a
gain of 1 independently of the associated damping. The filter is activated via machine data MD
1200 and MD 1201.

Damping current setpoint filter 3

1207

Default value

Lower input limit

Upper input limit

Units

1.0

0.05

5

Active

at once

Input of damping for current setpoint filter 3 (PT2 low-pass). The filter is activated via machine
data MD 1200 (selection current setpoint filter) and MD (type current setpoint filter) 1201.

7–58

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

SINUMERIK 840C (IA)