4 plc status – Siemens SINUMERIK 840C User Manual

Page 61

Advertising
background image

09.95

Siemens AG 2001

All Rights Reserved

6FC5197–

j

AA50

3-11

SINUMERIK 840C (IA)

3.5.4

PLC status

In the “PLC STATUS” mode, the user can read out the contents of counters and
timers and read out and write input words, output words, flag words, data words
and data double words. These words can only be written when a password has
been entered.

Selection

S

Up to software version 2:

SK “Diagnosis” –> SK “NC diagnosis” –> SK “Service display” –> SK “PLC
error recognition”

S

Software version 3 and higher:

SK “Diagnosis” –> SK “Service display” –> SK “PLC service”

IW

QW

FW

DB

DX

C

T

KM

KH

KF

KT

KC

DW

DD

parallel

KH

KF

Data areas

Read

Write

Data number

Input word

x

x

0–126

Output word

x

x

0–126

Flag word

x

x

0–254

Data word

x

x

0–254

Data double word

x

x

0–254

Times

x

0–255

Counter

x

0–255

Operator entries in
PLC STATUS mode

Any existing byte number may be preselected

Page DOWN:

The byte number is incremented by one

Page UP:

The byte number is decremented by one

3 PLC Installation

3.5.4 PLC status

Advertising