Siemens SINUMERIK 840C User Manual

Page 184

Advertising
background image

09.95

Siemens AG 2001

All Rights Reserved

6FC5197–

j

AA50

5–56

SINUMERIK 840C (IA)

for which the following short-hand notation can now be used (SW 4 and higher):

Example:
1500:1–8

By resorting it is possible to display in the usual way first all the data of the first
parameter set, then the data of the second parameter set, etc.

Example:
1407:1
1409:1
1500:1
...
1407:2
1409:2
1500:2
...
1407:3
1409:3
1500:3
...

Displaying the current

A special function now makes it possible to display one data at

parameter set only

a time, in each case that of the selected parameter set.

This function is used in the supplied system displays.

The individual data remain intrinsically independent, i.e. they can all have diffe-
rent texts and characteristics.

In order to apply this function, the data numbers in the data list are enclosed in
parentheses and a “G” is placed before the number of the parameter set group.

Example:
G1 ( 2040
15400
15440
15480
15520
15560
15600
15640 )

As a result, of these 8 data only the one belonging to the active parameter set of
the group “Position control” is displayed.

The arrangement (one above the other, next to one another) is irrelevant.

The abbreviated notation used in the past can be used in the brackets.

Example:
G3 ( 1500:1–8 )

Displaying the current

Definition of term: The axis number, channel number, spindle number,

parameter set selection transformation block number, drive number, slot number, IKA relation number,

IKA curve number and IKA point number are all referred to below as “Parameter
number”.

Display of the current parameter set selection is configured in the same way as
the current parameter number in the headline of the data list using the command
“headline”.

Previously, it was possible to configure the parameter designation and the current
parameter number here. As from SW 4, the axis name can also be displayed.

5 Machine Data Dialog (MDD – as from SW 3)

5.10.3 Configuring the parameter set switchover in the list display

Advertising
This manual is related to the following products: