Siemens SINUMERIK 840C User Manual

Page 546

Advertising
background image

09.95

7 Drive Machine Data (SIMODRIVE Drive MD)

7.3.2 Drive MD (data description)

5

4 k

20.0

-60.0

5

4 k

180

Phase

Deg

-180

Log Hz

Log Hz

fz

= 900 Hz

fbn = 1800 Hz (Dn = 100%)
fbz = 36 Hz (Dz = 2%)
fn

= 100%

dB

Note:

The value entered in MD 1516 (Numerator bandwidth speed setpoint filter 1) must not be
greater than twice the value set in MD 1515 (bandwidth speed setpoint filter 1).

Stop frequency speed setpoint filter 2

1517

Default value

Lower input limit

Upper input limit

Units

3 500.0

1.0

7 999.0

Hz

Active

at once

The description of this machine data is the same as that for machine data MD 1514!

Bandwidth speed setpoint filter 2

1518

Default value

Lower input limit

Upper input limit

Units

500.0

5.0

7 999.0

Hz

Active

at once

Input of 3dB bandwidth for speed setpoint filter 2 (band-stop). The filter is activated via
machine data MD 1500 (No. speed setpoint filters) and MD 1501 (Type speed setpoint filter).

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50