Siemens SINUMERIK 840C User Manual

Page 221

Advertising
background image

6 NC Machine Data (NC MD), NC Setting Data (NC SD)

09.95

6.4 Axis-specific MD 1 (axial data 1)

6.4

Axis-specific MD 1 (axial data 1)

Assignment of axis to actual-value port (analog)

200*

Default value

Lower input limit

Upper input limit

Units

0

+0

05030000

Active on

Power On

Simulation axes and spindles are defined if no measuring system has been parameterized (no
servo loop and encoder defined in MD 200* and MD 400*).

The simulation axis derives the partial actual values from the partial setpoints and therefore
"traverses" without any following error. Reference point approach with simulation axes is not
possible. Contour monitoring and P feedforward control are always inactive.

0

7

6

5

4

3

2

1

Digit No.

0

1

0

1

0

0

0

0

No. of servo

loop module

No. of

servo loop

Code

analog

drive

Axis number of the servo loop module
(entered by the control)

Example for structure
of a value in
MD 200*

Of no significance in the case of NC MD 384* (always 0)

Setpoints 1, 2, 3
(identifier 4, 5, 6)

Basic module

1

3

2

Output

2 Input

3 Input

1 Input

Output

Output

3

2

1

Submodule
slot 2

Submodule
slot 3

Submodule
slot 1

4

5

6

7

8

9

10
11

12

Input

Input

Input

Inputs or
outputs
depending
on sub-
module
type

No. of servo loop connector
HMS servo loop module

No. of servo loop connector
SPC servo loop module

MD 200

*

specifies the servo loop module or input for incoming actual position values.

All servo loop modules are interfaced to the same bus and are therefore numbered
automatically from left to right by the software on POWER ON. There is no wiring block for
these modules.

NC MD 384* is used to define the setpoint outputs.

Note:

See Section 5, Machine Data Dialog, for the servo loop assignment.

6–36

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

SINUMERIK 840C (IA)

Advertising
This manual is related to the following products: