09.95

8 PLC Machine Data (PLC MD)

8.5 PLC MD for the operating system (system bits)

6032

DL 16

DR 9

DL 9

DR 8

DL 8

DR 7

DL 7

DR 6

DL 6

6033

DR 16

DR 11

DL 11

DR 10

DL 10

PLC MD

DB63

DW No.

Bit No.

7

6

5

4

3

2

1

0

Alarm channel DB

Alarm channel DB

Default value:

All bits default to 0

Bit = 0

The system software does not evaluate the bits in the corresponding interface
byte for error messages.

Bit = 1

The system software evaluates the bits in the corresponding interface byte for
error messages.

Note:

The bit applies to all channels. If the corresponding bit is also set for operational messages
(PLC MD 6040/6041), the PLC goes into the stop loop in the startup routine.

Sample application:

Error message evaluation when a DR8 bit is "1": PLC MD 6032.5=1
Bit 9.5 in channel 2 (DB 11) results in output of error message number 6145 (see PLC
Installation Section).

6034

DL 17

DR k+3

DL k+3

PLC MD

DB63

DW No.

Bit No.

7

6

5

4

3

2

1

0

Alarm DB 31

Default value:

All bits default to 0

K = 0, 4, 8, 12, 16, 20 (1st to 6th spindle)

Bit = 0

The system software does not evaluate the bits in the corresponding interface
byte for error messages.

Bit = 1

The system software evaluates the bits in the corresponding interface byte for
error messages.

Notes:

1) The bit applies to all spindles.

2) If the corresponding bit is also set for operational messages (PLC MD 6042), the PLC

goes into the stop loop in the startup routine.

Sample application:

DB 31 D 7.9

1 signal error message 8021;

PLC MD 6034.0=

1 (See PLC Installation Section)

© Siemens AG 1992 All Rights Reserved 6FC5197- AA50