Siemens SINUMERIK 840C User Manual

Page 397

Advertising
background image

6 NC Machine Data (NC MD), NC Setting Data (NC SD)

01.99

6.10 MDs for flexible memory configuration

Load MS drive software (as from SW 6)

60003

Default value

Lower input limit

Upper input limit

Units

0

0

1

POWER ON

If MD 60003 and/or 60004 are set to 1 the memory for the drive software is automatically set
to 192/384 Kbytes (compatible memory requirement). The memory size can also be altered by
changing MD 60014 (toggling).

The following toggling options are available:

MD 60003 and MD 60004=0

MD 60014

0 Kbytes

MD 60003 or MD 60004=1

MD 60014

288 192 Kbytes

MD 60003 and MD 60004=1

MD 60014

576 384 192 Kbytes

Note:

See also function ”Flexible memory configuration”.

Memory for drive software for FDD as from SW 4

60004

Default value

Lower input limit

Upper input limit

Units

0

0

1

Active

after SK

"Reconfigure

memory"

If an area of the memory is reserved for FDD drive software, 194 KB memory is occupied.
Zero means no memory. The memory is only required for digital drives. The software only
loads the FDD software if the memory has been reserved for it.

Note:

The meaning of this machine data changes as from SW 6.

Load FD drive software (as from SW 6)

60004

Default value

Lower input limit

Upper input limit

Units

0

0

1

POWER ON

See machine data 60003.

Number of tools as from SW 4

60005

Default value

Lower input limit

Upper input limit

Units

819

1

1 637

1 TO

Active

after SK

"Reconfigure

memory"

The upper input limit depends on the number of parameters per tool (see MD 60006) and the
number of R parameters (see MD 60007/60008).

Note:

The standard tool management (FB package 1) still uses the values in MD 5019,
bit 0 and 1.