Siemens SINUMERIK 840C User Manual

Page 241

Advertising
background image

6 NC Machine Data (NC MD), NC Setting Data (NC SD)

09.95

6.4 Axis-specific MD 1 (axial data 1)

u: Variable increment weighting pulses

364*

Default value

Lower input limit

Upper input limit

Units

1

1

65 000 (SW 1)

9999 9999 (as from SW 2)

Active on

Power On

v: Variable increment weighting traversing path

368*

Default value

Lower input limit

Upper input limit

Units

2

1

65 000 (SW 1)

9999 9999 (as from SW 2)

Active on

Power On

The pulses coming from the digital measuring system and the position control resolution must
be coordinated in order to produce a correctly closed position control loop.

NC machine data 364* and 368* can be used for this purpose.

The number of pulses of the encoder and the appropriate distance to go on the machine must
be known for determining machine data 364* and 368* .

The following formula represents the relation between these machine data:

Position

control

resolution

×

MD

368*

=

Measuring

system

resolution

×

MD

364*

Schematic block diagram of the position control parameters :

Comput. resoln.

Actual value adjustment

Meas. system resolution

=

Meas.

system

Mech.

gearing

Pulses

Pulse eval.

MD 364*

Pos. control

resolution

MD 1800*

Dist. to go

Pulse eval.

MD 368*

=

Multipl.

of pulses

Hardware

Note concerning upper input limits

MD 364* and MD 368* should always be reduced as much as possible (at least for values
100 000).

Note: as from SW 4

MD 3900* 3904* and 3908* in the MDD are used to automatically calculate MD 364*.

6–56

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50