6 NC Machine Data (NC MD), NC Setting Data (NC SD)

09.95

6.4 Axis-specific MD 1 (axial data 1)

u: Variable increment weighting pulses

364*

Default value

Lower input limit

Upper input limit

Units

1

1

65 000 (SW 1)

9999 9999 (as from SW 2)

–

Active on

Power On

v: Variable increment weighting traversing path

368*

Default value

Lower input limit

Upper input limit

Units

2

1

65 000 (SW 1)

9999 9999 (as from SW 2)

–

Active on

Power On

The pulses coming from the digital measuring system and the position control resolution must
be coordinated in order to produce a correctly closed position control loop.

NC machine data 364* and 368* can be used for this purpose.

The number of pulses of the encoder and the appropriate distance to go on the machine must
be known for determining machine data 364* and 368* .

The following formula represents the relation between these machine data:

Position

control

resolution

×

MD

368*

=

Measuring

system

resolution

×

MD

364*

Schematic block diagram of the position control parameters :

Comput. resoln.

Actual value adjustment

Meas. system resolution

=

Meas.

system

Mech.

gearing

Pulses

Pulse eval.

MD 364*

Pos. control

resolution

MD 1800*

Dist. to go

Pulse eval.

MD 368*

=

Multipl.

of pulses

Hardware

Note concerning upper input limits

MD 364* and MD 368* should always be reduced as much as possible (at least for values
100 000).

Note: as from SW 4

MD 3900* 3904* and 3908* in the MDD are used to automatically calculate MD 364*.

6–56

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

SINUMERIK 840C (IA)

Advertising
This manual is related to the following products: