Siemens SINUMERIK 840C User Manual

Page 572

Advertising
background image

07.97

7 Drive Machine Data (SIMODRIVE Drive MD)

7.3.2 Drive MD (data description)

Motor temperature

1702

Default value

Lower output limit

Upper output limit

Units

0

0

32 767

°C

Active

at once

This machine data is used to display the motor temperature. The motor temperature is
measured by appropriate sensors and evaluated in the drive.

Lead time conver. motor meas. syst. (up to SW 4)

1703

Default value

Lower output limit

Upper output limit

Units

0

0

32 767

µ

s

Active

at once

This machine data is used to display or diagnose the lead time for the motor measuring
system converters. A converter lead time is required if the converter times are greater than the
ASIC cycle time. This machine data is valid only for indirect measuring systems.

Lead time conversion dir. meas. sys. (up to SW 4)

1704

Default value

Lower output limit

Upper output limit

Units

0

0

32 767

µ

s

Active

at once

This machine data is used to display or diagnose the lead time for the motor measuring
system converters. A converter lead time is required if the converter times are greater than the
ASIC cycle time. This machine data is valid only for direct measuring systems.

Voltage setpoint (effective) (as from SW 6)

1705

Default value

Lower output limit

Upper output limit

Units

V

eff

(line-to-line)

Active

at once

Voltage setpoint display. The signal can be output via DAC.

MD 1705 =

U

2

qset

+ U

2

dset

Speed setpoint

1706

Default value

Lower output limit

Upper output limit

Units

0.0

-100000.0

100000.0

rev/min

Active

at once

This machine data is used to display the speed setpoint which represents the unfiltered
summation setpoint. It comprises the component of the position controller output and the
speed feedforward control arm. Time-synchronous unlatching (scanning) of machine data MD
1706, MD 1707 and MD 1708 is not provided. The appropriate machine data is unlatched by
the read request of the non-cyclical communications protocol.

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

7–157

SINUMERIK 840C (IA)

Advertising
This manual is related to the following products: