Siemens SINUMERIK 840C User Manual

Page 201

Advertising
background image

6 NC Machine Data (NC MD), NC Setting Data (NC SD)

12.93

6.2 General machine data (general data)

Positions 2 to 32 of the feedrate override switch

100 - 130

Default value

Lower input limit

Upper input limit

Units

see below

0

150

%

Active

at once

Use can be made of a feedrate override switch with up to 32 positions. The percent figures
may be allocated as required except the far left (i.e. first) position, which is always 0 %. In
contrast to position 1, FST (Feed Stop) is not shown in the on-screen channel status field
when 0 % is allocated to another switch position.

Allocations exceeding 150 % are possible, but 150 % is set in the NC as internal limiting
value.

Default values:

1, 2, 4, 6, 8, 10, 20, 30, 40, 50, 60, 70, 75, 80, 85, 90, 95, 100, 105, 110, 115, 120, the
remaining NC MD (NC MD 122 to 130) are set to zero.

Positions 1 to 16 of the spindle override switch

131 - 146

Default value

Lower input limit

Upper input limit

Units

see below

50

150

%

Active

see below

Active: when all channels of the mode group are in STOP status.

Percentages may be assigned as needed to the max. 16 spindle override switch positions.

Default values:

50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 105, 110, 115, 120.

Positions 1 to 8 of the rapid traverse override switch

147 - 154

Default value

Lower input limit

Upper input limit

Units

see below

0

100

%

Active

at once

Default values: 1, 10, 50, 100, 0, 0, 0, 0.

Rapid traverse override must be activated via PLC interface signals. Also refer to the
description of NC MD 5004, bit 4.