12 Functional Descriptions

12.25.4 Memory configuration on control power-up

Fig. 2

Start-up/Machine data/NC MD/Memory configuration

DRAM memory configuration

General configuration

60000

Size of UMS memory

256 KB

60001

Size of part program memory

704 KB

60002

Number of IKA points

200

at 16 B

60003

Load MSD drive software

yes

0 KB

60004

Load FDD drive software

yes

0 KB

60014

Memory for MSD/FDD drive software

384 kB

60013

Number of real axes

15

16 KB

Number of block buffers per channel

61000

Channel 1

23

at 1588 B

61001

Channel 2

23

at 1588 B

61002

Channel 3

23

at 1588 B

61003

Channel 4

23

at 1588 B

61004

Channel 5

23

at 1588 B

61005

Channel 6

23

at 1588 B

Free remaining memory - DRAM data:

29 772 bytes

Free remaining memory - SRAM data:

13 552 bytes

Find

ncmemcfg

Copy

spindle

Insert

spindle

Insert

axis

Machine

Parameter

Program.

Services

Diagnosis

DRAM

data

SRAM

data

Reconfig.

memory

File

functions

Copy

axis

To ensure that this plausibility check works, the MDD fetches various information such as

memory requirements for one block buffer (may vary depending on SW version installed)

size of configurable DRAM memory, etc.

from the NC when display 2 is selected.

This information is required in order to calculate the free remaining memory and to monitor the
values entered in displays 2, 3 and 4.