Siemens SINUMERIK 840C User Manual

Page 134

Advertising
background image

+

Copy to
clipboard

Paste from
clipboard

09.95

Siemens AG 2001

All Rights Reserved

6FC5197–

j

AA50

5–6

SINUMERIK 840C (IA)

Current controller:
MD 1120

P gain current controller (FDD/MSD)

MD 1121

Reset time current controller (FDD/MSD)

Flux controller:
MD 1150

P gain flux controller (MSD)

MD 1151

Reset time flux controller (MSD)

Torque and output limits:
MD 1230

1st torque limit (FDD)

MD 1235

1st output limit (FDD)

Speed interface normalization:
MD 1401

Speed for max. motor working
speed (FDD/MSD)

Speed controller:
MD 1147

Speed limitation (FDD/MSD)

MD 1405

Monitoring speed motor (FDD/MSD)

MD 1407

P gain speed controller (FDD/MSD)

MD 1408

P gain upper adaptation speed (MSD)

MD 1409

Reset time speed controller (FDD/MSD)

MD 1410

Reset time upper adaptation speed (MSD)

MD 1411

Lower adaptation speed (MSD)

MD 1412

Upper adaptation speed (MSD)

MD 1413

Selection adaptation speed controller (MSD)

AM operation:
MD 1451

P gain speed controller AM (MSD)

MD 1453

Integral action time speed controller AM (MSD)

MD 1466

Changeover speed closed/open loop control AM (MSD

MD 1465

Changeover speed MSD/AM (MSD only when MD 1011.5=1)

MD 1608

Fixed temperature (MSD only when MD 1011.5=1)

v/f operation:
MD 1127

Voltage with f=0 V/F-mode (MSD)

Please note that any controller data entered manually will
be overwritten when softkey Calculate controller data is
pressed!

Selecting displayed data in header (SW 4 and higher)
You select the displayed parameter number (top left) for position control, ratio
and drive and the displayed axis number for the axis by pressing the Shift and
the Home hardkeys simultaneously.

Explanation

With these keys it is possible to enter the data directly in all displays in which the
current data are displayed in the header. It is also possible to toggle and move
forwards/backwards with the +/– and select keys. The cursor remains positioned
on the parameter number in the header until either a correct number has been
entered or the Enter, Shift-Home, Backspace, Delete, Cursor key has been
operated and the field is exited without making any changes.

Note

This function replaces the previous Search local function for IKA 2 (IKA curve
pointer) and IKA 3 (IKA error points).

Example of application:
Copying data from one axis into another axis.

5 Machine Data Dialog (MDD – as from SW 3)

5.1.1 General notes on operation

Advertising
This manual is related to the following products: