Siemens SINUMERIK 840C User Manual

Page 655

Advertising
background image

Configur.
DAC

09.95

Siemens AG 2001

All Rights Reserved

6FC5197–

j

AA50

9–34

SINUMERIK 840C (IA)

Note

The test sockets on 611D modules have an output voltage of between 0 and 5 V;
611A modules have a +/–10 V output. The test sockets can be evaluated in the
usual way. These sockets are not intended for use in normal operation.

Anwahl

Diagnosis

Drive servo
startup

Start-up

Configur.
DAC

Configur.
mixed I/O

Fig. 9.14

Explanation

In this display, the output DACs are assigned via drive selection (+/–) and speci-
fication of the axis/spindle name.

The offset input values must make allowance for the output range of the analog
voltage signal. The 611D drive module DACs have an output range of –2.5 V to
2.5 V.

Since the DAC resolution is limited (8 bits), a window can be placed over the
output value by means of the shift factor, i.e. the signal output is decreased
(normalization) when a negative shift factor is input and is increased
(normalization) with a positive shift factor. The input limits for the shift factor vary
for SERVO, FDD and MSD:

9 Drive Servo Start-Up Application (as from SW 3)

9.4 Mixed I/O configuration and digital-analog converter, DAC (as from SW 3)