Siemens SINUMERIK 840C User Manual

Page 289

Advertising
background image

6 NC Machine Data (NC MD), NC Setting Data (NC SD)

04.96

6.6.1 General MD bits (general bits)

7

6

5

4

3

2

1

0

Bit No.

NC MD

5020

Emergency

retraction

off (as from

SW4.7

SW 5.2)

Default value:

0

Bit 2

Bit 2 = 1

Emergency retraction off (G420) for all channels
Meaning:
Monitoring of the ER sources, specified via MD, OFF for:
-

the channel where the part program is executed

-

all axes of the mode group for ALL channels incl. PLC

-

all spindles of the mode group for ALL channels incl. PLC

G420 X S1 =
Meaning:
Monitoring of the ER sources, specified via MD, OFF for:
-

the X axis for ALL channels incl. PLC

-

the spindle S1 for ALL channels incl. PLC

”G420/G421” from PLC:
Axis-specific:

DB29

DR K+ 2.5

DL K+ 2.5

Spindle-specific:

DB29

DR K+ 26.5

DL K+ 26.5

Monitoring for axes (FA/FS) can also be switched on/off from PLC. If
monitoring is switched off from PLC, it is switched off for all channels.

Bit 2 = 0

Emergency retraction off (G420) in current channel

7

6

5

4

3

2

1

0

Bit No.

NC MD

5021

Neutral

position of

outputs for

mode group

6

1)

Neutral

position of

outputs for

mode group

5

1)

Neutral

position of

outputs for

mode group

4

1)

Neutral

position of

outputs for

mode group

3

1)

Neutral

position of

outputs for

mode group

2

1)

Neutral

position of

outputs for

mode group

1

1)

Neutral position of mixed I/O outputs bit 5 to 0

Bit 5-0=1

After Mode Group Reset the output byte of the mixed I/O module is at high
level (24 V).

Bit 5-0=0

After Mode Group Reset the output byte of the mixed I/O module is at low
level (0 V).

Active:

On Power On

_______

1)

As from SW 4

6–104

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

SINUMERIK 840C (IA)

Advertising