09.95

6 NC Machine Data (NC MD), NC Setting Data (NC SD)

6.9 MDs for parameter set switchover

Zero mark correction + as from SW 4

5th to 8th parameter set

2430*-

2433*

Default value

Lower input limit

Upper input limit

Units

0

- 999 999

999 999

16 000 (as from SW 4.4)

units (MS)

Active on
NC Stop

Zero mark correction - as from SW 4

1st to 8 th parameter set

2434*-

2441*

Default value

Lower input limit

Upper input limit

Units

0

- 999 999

16 000 (as from SW 4.4)

999 999

16 000 (as from SW 4.4)

units (MS)

Active on
NC Stop

These MDs are used to correct gear-stage-related offsets between the zero mark and
reference position, see functional description of "”Ratio” parameter group".

Feedforward control factor 2nd - 8th parameter set

as from SW 4

2442*-

2448*

Default value

Lower input limit

Upper input limit

Units

0

0

1 000

0.1 %

Active on
NC Stop

These MD have the same meaning as MD 465*, see also functional description of parameter
set switchover.

Feedforward control factor D component as from SW 4

1st to 8 th parameter set

2449*-

2456*

Default value

Lower input limit

Upper input limit

Units

0

0

1 000

0.1 %

Active on
NC Stop

Time constant symm. filter 2nd - 8th par. set as from SW 4

2457*-

2463*

Default value

Lower input limit

Upper input limit

Units

0

0

9 999

1 000 (as from SW 4.4)

0.1 ms

Active on
NC Stop

These MD have the same meaning as MD 467*, see also functional description of parameter
set switchover.

Time constant setpoint filter 2nd - 8th par. set

as from SW 4

2464*-

2470*

Default value

Lower input limit

Upper input limit

Units

55

0

1 000

16 000 (as from SW 4.4)

0.1 ms

Active

at once

These MD have the same meaning as MD 486*, see also functional description of parameter
set switchover.

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

6–197