6 NC Machine Data (NC MD), NC Setting Data (NC SD)

09.01

6.2 General machine data (general data)

2.

Delay for removal of the servo enable signal on the measuring circuit following

"EMERGENCY STOP" and other errors resulting in immediate shutdown of the axes (e.g.

contour monitoring).

3.

Delay for removal of the servo enable signal on the measuring circuit when the PLC

revokes the servo enable for an axis.

4.

MD 156 is only active if MD 1224* is set to zero (servo enable delay).

Types of control for standard cycles

157

Default value

Lower input limit

Upper input limit

Units

see below

Active

Identifier

Software version

Entry in

MD 157

SINUMERIK

840CT

61

1.1

6111

840CM

62

1.1

6211

MD 157 is loaded by the NC software, and must not be changed manually.
It is used by the standard cycles, i.e. measuring cycles for the relevant control.
The applicable Software Version is only displayed in on-line mode, it is entered by the NCK

system software during runup.

Interpolation cycle

160

Default value

Lower input limit

Upper input limit

Units

4

2 *

32

Active on

Power On

In order to compensate for the fact that a machine's axes frequently differ in dynamic

response, the SINUMERIK 840C has been designed so that the operator can specify the ratio

of interpolation to position control (sampling interval = MD 155). The interpolation time is the

product obtained by multiplying the contents of MD160 with the contents of MD155. See

Section Axis (Analog) and Spindle Installation.

Number of IKA configurations via PLC/DB48

161

Default value

Lower input limit

Upper input limit

Units

0

0

32

Activve

immediately

By means of MD161 the number of IKA configurations is limited which can be controlled via

the PLC interface DB48. This MD is only effective with or released by MD 5189 bit 7=1.
Example: MD161=3

In DB48, the data words DW 16 to 73 are no longer processed. The interface is only updated

for IKA 1 to 3 (DW 10 to 15). The IKA center DW8 still applies only to DW10 to DW15. See

also the table below.

DW k

DW k+1

IKA n

DW k

DW k+1

IKA n

10

11

1

2n+8

2n+9

N

12

13

2

...

...

...

14

15

3

72

73

32

...

...

...

Explanation of the table (extract from DB48):

n= IKA number (IKA1 ... IKA32), k= data word number of DB48 (DW k)

The following is valid for all data words DW 'k'=10, 12, 14...72 (input signals: PLC to NCK):

k=2n+8

or n=(k-8)/2

The following is valid for all data words DW 'k+1'=11, 13, 15...73 (output signals: NCK to

PLC):

'k+1'=2n+9

or n=('k+1'-9)/2

_______

*

The lower limits only apply if the control is operated from a channel.

6–18

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

SINUMERIK 840C (IA)