Siemens SINUMERIK 840C User Manual

Page 177

Advertising
background image

09.95

Siemens AG 2001

All Rights Reserved

6FC5197–

j

AA50

5–49

SINUMERIK 840C (IA)

5.9.7

Reinstallation of existing and new drive components using the
existing drive files (TEA3)

Application

You require a two-tier configuration, i.e. a 2nd module group is to be added.
TEA3 user files already exist for the individual modules and motors.

Procedure

Select the File functions softkey in the configuring display and then operate the

(1st method)

Load from disk softkey. A menu bar appears in which you enter the existing
TEA3 files together with the file names and then select the Config area with the
toggle key.
Operate the Load start softkey. The data are loaded into the drive. Confirm these
settings with the Accept conf + NCKP0 softkey.

Fig. 5.23

Procedure 1

Again select the drive configuration display and the File functions softkey. Using

(2nd method)

the Load from disk softkey, load the TEA3 files in the Drives area into the drive
using the Load start softkey. Confirm this setting with the Accept all + NCKP0
softkey.

5 Machine Data Dialog (MDD – as from SW 3)

5.9.7 Reinstallation of existing and new drive components using the existing drive files (TEA3)

Advertising