7 Drive Machine Data (SIMODRIVE Drive MD)

07.97

7.3.2 Drive MD (data description)

Motor no-load voltage

1135

Default value

Lower input limit

Upper input limit

Units

0.0

0.0

500.0

V

Active

at once*

Input of motor no-load voltage as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 1102).

Note:

This data is relevant only for MSD drives.

* Active on "Power On" until SW < 6

Motor no-load current

1136

Default value

Lower input limit

Upper input limit

Units

0.0

0.0

500.0

A

Active

at once*

Input of motor no-load current as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 1102).

Note:

This data is relevant only for MSD drives.

* Active on "Power On" until SW < 6

Stator resistance cold

1137

Default value

Lower input limit

Upper input limit

Units

0.0

0.0

120.0

Active

at once*

Input of stator resistance (cold) as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 1102).

Note:

This data is relevant only for MSD drives.

* Active on "Power On" until SW < 6

Rotor resistance cold

1138

Default value

Lower input limit

Upper input limit

Units

0.0

0.0

120.0

Active

at once*

Input of rotor resistance (cold) as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 1102).

Note:

This data is relevant only for MSD drives.

* Active on "Power On" until SW < 6