Siemens SINUMERIK 840C User Manual

Page 782

Advertising
background image

06.93

12 Functional Descriptions

12.1.2 Functional description

813

793

790

Spacing

Tra-
verse
path

Error=0

Pos.
error

Reference point

Neg.
error

Example

Axis 1 shows the error curve; no compensation points have been used as yet.

Reference point value is 0

Max. - travel:

- 35.000 mm

Max. + travel:

+ 205.00

mm

Tolerance band (prescribed by machine manufacturer), e.g. 0.01 mm
Spacing between two leadscrew error compensation points, e.g. 10 mm :

235 mm traverse path/max

A-

3 compensation values

10 mm grid spacing

205 mm traverse path/max+

A+

20 compensation values

10 mm grid spacing

Total number of compensation values:

K =( A-) +( A+) + (Ref) = 3 + 20 + 1

24 compensation values

The result is NC MD 3161 = 1 (NC MD 6001), i.e. compensation point K5 is the point that
corresponds to the reference point; compensation at this point is not allowed. Compensation
point K4 is used when travel goes 10 mm in a negative direction, and K6 when travel goes
10 mm in a positive direction.

© Siemens AG 1992 All Rights Reserved 6FC5197- AA50