3 channel-specific md (channel data) – Siemens SINUMERIK 840C User Manual

Page 216

Advertising
background image

10.94

6 NC Machine Data (NC MD), NC Setting Data (NC SD)

6.3 Channel-specific MD (channel data)

6.3

Channel-specific MD (channel data)

Mode group

100*

Default value

Lower input limit

Upper input limit

Units

1

1

0 (SW 4 and higher)

2

6

1)

Active on

Power On

Warm restart

MD 1000 must be set to "1" (default).

Gaps are not allowed in MD 100*. If an error occurs, alarm 79 ”Mode group no. of channel
invalid” is issued.

Example

1000

1

1001

2

1002

0

1003

0

1000

1

1001

0

1002

2

1003

0

allowed

not allowed

TO area for channel

104*

Default value

Lower input limit

Upper input limit

Units

1

1

4

6

1)

Active

at once

The TO area for each channel is entered in NC MD 104*. The maximum value must accord
with NC MD 210. A TO area must be allocated to each channel. Also refer to NC MD 210 to
214.

No. of the enabled program

106*

Default value

Lower input limit

Upper input limit

Units

0

±see below

± see below

Active in

next block

If 0 is entered, all programs are enabled in the first processing level for this channel. The
program number must be entered if only a particular program may be started in a channel in
the first processing level.

This may serve a practical purpose particularly when only a specific motion may be executed
in a channel, i.e. with respect to loaders, tool palleting, and the like.

Main programs:

1

to +9999

Subprogram/cycle:

–1

to

–9999

All main programs and subprograms:

0

_______

1)

As from SW 4

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

6–31

SINUMERIK 840C (IA)

Advertising
This manual is related to the following products: