Siemens SINUMERIK 840C User Manual

Page 252

Advertising
background image

09.95

6 NC Machine Data (NC MD), NC Setting Data (NC SD)

6.5 Spindle-specific MD (spindle data)

MD 403*

MD 404*

MD 405*

MD 448*

Voltage

[volts]

Speed [rev/min]

10

MD 411*

MD 412*

MD 413*

U

max

If 3rd gear has been engaged, the new S value must be lower than the contents of MD 413* in
order for the NC to initiate a gear change.

U

max

: maximum setpoint speed voltage (MD 468*)

Acceleration time constant for eight gears

419*-426*

Default value

Lower input limit

Upper input limit

Units

800

+0

50 000

1 ms

Active on
NC Stop

Gear

1

2

3

4

5

6

7

8

NC MD

419*

420*

421*

422*

423*

424*

425*

426*

The control provides the setpoint for acceleration in the form of a ramp that is based on the
contents of these MD. The MD thus act as variable ramp-function generators. They are set by
measuring the interval from zero speed to maximum speed for each gear. NC MD 419*-426*
can be set to zero when the drive actuator is equipped with an integrated ramp-function
generator.

Notes:

There are two acceleration time constants for every stage:

Acceleration time constant without position controller (MD 419* to 426*)

Acceleration time constant without position controller (MD 478* to 485*)

In control mode the time constants are used without position control.
In positioning mode the time constants are used with position control.

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

6–67

SINUMERIK 840C (IA)

Advertising
This manual is related to the following products: