04.96

6 NC Machine Data (NC MD), NC Setting Data (NC SD)

6.9 MDs for parameter set switchover

D component comp. contr. 2nd - 8th par. set as from SW 4

2508*-

2514*

Default value

Lower input limit

Upper input limit

Units

0

0

16 000

1

Active on

RESET

These MD have the same meaning as MD 489*, see also ”Functional Descriptions: Parameter
set switchover”.

Time constant parallel model 2nd - 8th par. set

as from SW 4

2515*-

2521*

Default value

Lower input limit

Upper input limit

Units

6 000

0

16 000

0.01 ms

Active on

RESET

These MD have the same meaning as MD 490*, see also ”Functional Descriptions: Parameter
set switchover”.

Alarm limit speed as from SW 4 1st to 8th par. set

2522*-

2529*

Default value

Lower input limit

Upper input limit

Units

MD 403* ff.+10%

0

99 999

rpm/or 0.1 rpm

Active on
NC Stop

These machine data are active only with gear interpolation.

Alarm limit acc. constant as from SW 4 1st to 8th par. set

2530*-

2537*

Default value

Lower input limit

Upper input limit

Units

MD 478* ff.+10%

0

50 000

ms

Active on
NC Stop

These machine data are active only with gear interpolation.

Tol. band synchr. "fine" 2nd - 8th par. set as from SW 4

2546*-

2552*

Default value

Lower input limit

Upper input limit

Units

40

0

16 000

99 999 999 (SW5.4

and higher)

1 unit (MS)

Active on

RESET

These MD have the same meaning as MD 491*, see also ”Functional Descriptions: Parameter
set switchover”.

Tol. band synchr. "coarse" 2nd - 8th par. set as from SW 4

2553*-

2559*

Default value

Lower input limit

Upper input limit

Units

100

0

16 000

99 999 999 (SW5.4

and higher)

1 unit (MS)

Active on

RESET

These MD have the same meaning as MD 492*, see also ”Functional Descriptions: Parameter
set switchover”.

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

6–199

SINUMERIK 840C (IA)

Advertising