6 NC Machine Data (NC MD), NC Setting Data (NC SD)

09.95

6.2 General machine data (general data)

The number of areas is specified in NC MD 210. The number of TO areas is limited to
between 1 and 4. One TO area is provided when a value of 0 is entered. If the specified value
exceeds 4, it is set to 4 internally and alarm 47 triggered.

The limits of the TO areas are defined by specifying the TO start numbers in NC MD 211 to
214. The last TO area extends from the last value specified in NC MD 211 - 214 to the
maximum tool offset number (observe NC MD 13 and 104x).

Caution!

A modification does not become effective until user memory is formatted. In "Overall Reset"
mode, user memory is formatted with the "Format User Data" or "Format TO Data" softkey.
For detailed information on invoking the "Overall Reset" mode, refer to Section General Reset.

Initial D no. for TO area 2

212

Default value

Lower input limit

Upper input limit

Units

see below

1

809 *

Active same

as MD 210

Initial D no. for TO area 1

211

Active same

as MD 210

Initial D no. for TO area 3

213

Active same

as MD 210

Initial D no. for TO area 4

214

Active same

as MD 210

Default value:

211 = 1, 212, 213, 214 = 0

The data location numbers for TO areas 1 to 4 must be given in ascending order. Only one TO
area will be set internally and alarm 47 triggered if this rule is not observed. The TO areas are
allocated to the channels in NC MD 104*.

Example

NC MD

13

NC MD

210

NC MD

211

NC MD

212

NC MD

213

NC MD

214

Number of TO parameters

Number of TO areas

Initial D no. for TO area

1

Initial D no. for TO area

2

Initial D no. for TO area

3

Initial D no. for TO area

4

10

4

1

30

55

150

_______

*)

As from SW 4 see Flexible Memory Allocation