Siemens SINUMERIK 840C User Manual

Page 547

Advertising
background image

7 Drive Machine Data (SIMODRIVE Drive MD)

09.95

7.3.2 Drive MD (data description)

Note:

When 0 is entered for the bandwidth, the filter is parameterized as a proportional element with
a gain of 1.

Numerator bandwidth speed setpoint f. 2

1519

Default value

Lower input limit

Upper input limit

Units

0.0

0.0

7 999.0

Hz

Active

at once

The description of this machine data is the same as that for machine data MD 1516!

Band-stop filter natural frequency speed setpoint f. 1

1520

Default value

Lower input limit

Upper input limit

Units

100

1

141

%

Active

at once

Input of the band-stop filter natural frequency for raising or lowering the amplitude response
after the blocking frequency (MD 1514/1517).

The machine data (MD 1520/MD 1521) are used to match different axis dynamic responses to
a standard dynamic response (low-pass filter). The standard dynamic response is based on
that of the axis with the lowest resonant frequency.

Formula:

1+s · (2 ·

· fbz/(2 ·

· fz)

2

)+s

2

· (1/(2 ·

· fz)

2

)

1 + s · (2 · Dz/2 ·

· fz) + s

2

· 1/(2 ·

· fz)

2

–––––––––––––––––––––––––––––––––––––––––––––––––

––––––––––––––––––––––––––––––––––––––––––––

1+s · (2 ·

· fbn/(2 ·

· fn)

2

)+s

2

· (1/(2 ·

· fn)

2

)

1 + s · (2 · Dn/2 ·

· fn) + s

2

· 1/(2 ·

· fn)

2

Input:

fz

: Blocking frequency

MD 1514/1517

Dz

: Damping numerator

fbz = 2 · Dz · fz

: Bandwidth numerator

MD 1515/1518

Dn

: Damping denominator

fbn = 2 · Dn · fn

: Bandwidth denominator

MD 1516/1519

fn=MD 1520[%]·fz

: Band-stop filter natural
frequency

MD 1520/1521 (default value)

7–132

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

SINUMERIK 840C (IA)

Advertising
This manual is related to the following products: