Siemens SINUMERIK 840C User Manual

Page 989

Advertising
background image

12 Functional Descriptions

04.96

12.20 Extended stop and retract (ESR) (SW 4 and higher)

–

Application of internal sources:
-

Emergency retraction threshold FA/FS,

-

611D DC link voltage threshold, drive MD 1634,

-

611D generator speed threshold, drive MD 1635

which must initiate a retraction operation.

–

Definition of internal reactions to be initiated in the case of a retraction operation:
-

Alarm and mode group stop

-

Retraction operation as open-loop control function and/or as

-

Autonomous drive function

•

Drive parameters for the "Extended stop and retract" function (611D)

–

DC link voltage threshold, drive MD 1631: If the voltage drops below this limit, a
drive defined as the generator axis switches to generator mode.

–

Voltage step, drive MD 1632: This value defines the upper threshold of the two-
position controller for generator operation.

–

DC link voltage threshold, drive MD 1633: If the voltage exceeds this limit value,
the drive switches from generator mode back to normal operation.

–

DC link voltage threshold, drive MD 1634: If the voltage drops below this limit,
emergency retraction measures can be initiated according to user specifications
(via MD or programming).

–

Generator speed threshold, drive MD 1635: If the speed drops below this value,
emergency retraction measures can be initiated according to user specifications
(via MD or programming).

2.) The possibility of controlling the function via the PLC:

•

Channel-specific

–

To PLC:
-

ESR monitoring is active

-

ESR reaction is initiated

•

Axis/spindle-specific

–

From PLC:
-

Activate ESR monitoring

-

Disable ESR monitoring

-

Enable ESR reaction

–

To PLC:
-

ESR monitoring is active

-

ESR reaction is initiated

-

ESR reaction is programmed

-

611D ZK2 messages

•

If monitoring is switched on from the PLC, it can be switched off from the PLC only.

•

If monitoring is switched off from the PLC, it is switched off for all channels.

12–214