Siemens SINUMERIK 840C User Manual

Page 308

Advertising
background image

09.01

6 NC Machine Data (NC MD), NC Setting Data (NC SD)

6.6.1 General MD bits (general bits)

7

6

5

4

3

2

1

0

Bit No.

NC MD

5198

Compensa-

tion beyond

working area

(from SW

5.03.57)

Block

definition

from PLC

(as from

SW 4)

Extended
overstore

(as from

SW 4)

Jerk IPO

Ref. point

synch. via

G74

Default value:

0

Bit 7 Bit 7=1

Enables compensation beyond working area

Bit 7=0

Compensation beyond working area disabled

Bit 4 Bit 4=1

Enables block definition from PLC.

Bit 4=0

Block definition from PLC disabled.

Bit 3 Bit 3=1

Extended overstore enabled. Only checked if extended overstore is
selected.

Bit 2 Bit 2=1

Jerk-controlled interpolator active

Bit 2=0

Standard interpolator active (default setting)

Bit 0 Bit 0=1

Reference point synchronization

By selecting the function G74 you can approach the reference point in a
programmed axis in a program. The function works in a similar way to the
reference point approach in the reference point mode. You can only select
this function in AUTOMATIC and MDA modes for one axis at a time.

7

6

5

4

3

2

1

0

Bit No.

NC MD

5199

Display

PLC

message

texts (up to

SW 2)

R

parameter

extension

(up to

SW 2)

Default value:

0

Active:

On POWER ON

Bit 4 Bit 4=1 Storing PLC alarm texts (PCF) in the NC part program memory

The alarm texts are stored in the NC part program memory in the same way
as in an ASCII file. The block numbers in this alarm text program correspond
to the alarm number to which the text is allocated. This file can be read in and
out via the MMC/computer link and can be edited, deleted, renamed and
copied within the possibilities offered by part program processing with certain
restrictions regarding start-up and password.

If available, the alarm texts are taken from the program, otherwise the display
submodules search for the alarm text in the UMS.

Bit 3 Bit 3=1 R parameter extension

This function gives you more R parameters.

R parameters

Basic version

Expansion

Channel-specific

R00

-

R599

R600

-

R699

Central

R700

-

R899

R1000

-

R1299

This bit is activated when the softkey "Format R parameters" is pressed in
initial clear mode.

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50