6 NC Machine Data (NC MD), NC Setting Data (NC SD)

01.99

6.9 MDs for parameter set switchover

Maximum velocity (as from SW 6)

3392*-

3416*

Default value

Lower input limit

Upper input limit

Units

0

0

10 000

Active on
NC Stop

See also Functional Descriptions: Collision monitoring.

Compensation time constant for contour monitoring

3420*

(from SW 6.3)

Default value

Lower input limit

Upper input limit

Units

0

0

600

0.1 ms

Active

at once

When using a PT1 speed setpoint smoothing filter (drive MD 1502* or 1503*), the value
entered there must be entered under NC MD 3420*.

By gradually adjusting the input value NC MD 3420* (up or down), a setting can be found
resulting in still further reduced contour deviation during acceleration or deceleration
processes.