Siemens SINUMERIK 840C User Manual
Page 446

12.93
7 Drive Machine Data (SIMODRIVE Drive MD)
7.1.2 MSD MD (data description - SW 3)
Motor rated voltage motor 2
222
Default value
Lower input limit
Upper input limit
Units
Depends on motor
0
500.0
V
Active on
Power On
Input of motor rated voltage as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 238).
Motor rated speed motor 2
223
Default value
Lower input limit
Upper input limit
Units
Depends on motor
0
4 096
1/min
Active on
Power On
Input of motor rated speed as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 238).
Motor rated frequency motor 2
224
Default value
Lower input limit
Upper input limit
Units
Depends on motor
0
409.6
Hz
Active on
Power On
Input of motor rated frequency as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 238).
Motor no-load voltage motor 2
225
Default value
Lower input limit
Upper input limit
Units
Depends on motor
0
500.0
V
Active on
Power On
Input of motor no-load voltage as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 238).
Motor no-load current motor 2
226
Default value
Lower input limit
Upper input limit
Units
Depends on motor
0
200.0
A
Active on
Power On
Input of motor no-load current as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 238).
Stator resistance cold motor 2
227
Default value
Lower input limit
Upper input limit
Units
Depends on motor
0
32 767
m
Active on
Power On
Input of stator resistance (cold) as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 238).
©
Siemens AG 1992 All Rights Reserved 6FC5197- AA50
7–31
SINUMERIK 840C (IA)