7 Drive Machine Data (SIMODRIVE Drive MD)

04.96

7.3.2 Drive MD (data description)

Block frequency speed setpoint filter 1

1514

Default value

Lower input limit

Upper input limit

Units

3 500.0

1.0

7 999.0

Hz

Active

at once

Input of block frequency for speed setpoint filter 1 and parameterization as simple band-stop
filter. The filter is activated via machine data MD 1500 (number of setpoint filters) and MD
1501 (type speed setpoint filter). The machine data MD 1516/MD 1519 (bandwidth numerator
speed setpoint filter) and MD 1520/MD 1521 (band-stop filter natural frequency speed setpoint
filter) keep their default values.

Formula:

1+s · (2 ·

· fbz/(2 ·

· fz)

2

)+s

2

· 1/(2 ·

· fz)

2

H(s) = ––––––––––––––––––––––––––––––––––––––––––––––––

1+s · (2 ·

· fbn/(2 ·

· fn)

2

)+s

2

· 1/(2 ·

· fn)

2

Input:

fz

= MD 1514/1517

Blocking frequency speed setpoint 1/ speed setpoint 2 [Hz], (point
of resonance)

fbn

= MD 1515/1518

Bandwidth denominator filter 1/filter 2 [Hz]

fbz

= MD 1516/1519

Bandwidth numerator filter 1/filter 2 [Hz]

fn

= MD 1520/1521

Band-stop filter natural frequency filter 1/filter 2 [%] percentage with
reference to MD 1514 or MD 1517

MD 1520 (MD 1521)

fn =

–––––––––––––––––––· MD 1514 (MD 1517) [%]

100

Example:

20.0

dB

-60.0

5

Polynomial

4 k

Log Hz

180

Phase

Deg

-180

fz

= 900 Hz MD 1514/1517

fbn = 600 Hz MD 1515/1518
fbz = 0 Hz

MD 1516/1519
(Default value)

fn

= 100 %

MD 1520/1521
(Default value)

SYNTHESIS