11 Data Backup/CPU Replacement

01.99

11.1.7 Loading from hard disk (control startup with user data)

3

Boot file generated
Warning:
If this SK is not pressed,
all drive data will be lost
after ”Power on”!

54) SK ”Loading from disk”

55) Set ”Drives” area
via toggle switch

56) SK ”Loading start”

57) Press ”Recall” key

58) Vertical SK

Accept ”All” + ”NCK PO”

59) Machine display faded in

60) Area switchover

61) SK ”Diagnosis”

62) Press ”Recall” key twice

63) SK ”General reset mode”

64) SK ”Exit general reset mode”

65) ”Machine area” key

66) END

A

!!!Data transfer from PC to NC in progress!!!
Note:
PLC should be activated by this time
(only green LED light on the PLC CPU)

Note:

Missing data, e.g. TC, ZO, setting data

must be reloaded later.