Practical example for user adaptation list display – Siemens SINUMERIK 840C User Manual

Page 181

Advertising
background image

09.95

Siemens AG 2001

All Rights Reserved

6FC5197–

j

AA50

5–53

SINUMERIK 840C (IA)

List contents:

The texts for all data are stored in the text lists.

Text lists
Examples:

2040

“Exact stop limit coarse”

2080

“Exact stop limit fine”

5600.0

“No measuring circuit monitoring”

5600.2

“Rounding to whole/half degrees”

List contents:

The data type (L = long, C = 8 bits, S = short, etc.) and the display format, any

Semantic lists

special treatment and input limits are stored in the semantics lists.

Examples:

Data

Type

Treatment

Input limits

160

L

05

164

L

00

! (write-protected)

168

L

“0.0625 5.2 2”

[

2.32

]

208

L

72

[

1.99999999

]

The information under “Treatment” is interpreted as follows:

00

1:1 - representation

05 bzw. 07

special treatment or.

-representation

“0.0625 5.2 2”

Unit no.
(the units are in text list tea1unit.106)
5 places, of which 2 are behind the decimal point
Factor for display

List contents: Info lists

Explanations for all the data that appear in the information display (key

¼

) can

be stored in the information lists.

Example:

2040

“This data is not active until Power On”.

5.10.2

Practical example for user adaptation list display

Problem

“PLC machine data 2007 is supplied with the text ”Number of assigned maga-
zine” and with input limits 0 to 4

The user wishes to change this text to the following:
“Number of assigned tool turret”
and the input limits to 1 to 99.

5 Machine Data Dialog (MDD – as from SW 3)

5.10.2 Practical example for user adaptation list display

Advertising