12 Functional Descriptions

12.13.4 Machine data for the function ”Setup mode division related”

12.13.4

Machine data for the function ”Setup mode division related”

NC MD 1104*:

Name

: Number of divisions (ND)

Significance

: Number of divisions per reference dimension

Standard value

: 0

Input value limit

: 1 ... 999

Reference system

: ---

Input resolution

: ---

Active

: Every 100 ms

NC MD 1108*

Name

: Division reference dimension (DRD)

Significance

: Defines the reference to which the number of divisions

refers

Standard value

: 0

Input value limit

: Linear axis

Reference system

: MS (Machine System)

Input resolution

: units

Active

: Every 100 ms

Note:

The rotary axis has an internal reference dimension of 360 degress according to the input
resolution. No inputs necessary.

When using the functions with chain magazines, a rotary axis may need several revolutions to
match one magazine revolution.

The division reference remains in this case, however, 360 degrees. The rotary axis or chain
magazines can be matched with the variable incremental weighting.

NC MD 1112*:

Name

: Division offset

Significance

: Relation between actual value= 0 and indexing position 1

Standard value

: 0

Input value limit

: Linear axis

: +/ - 1 ... 99 999 999

Rotary axis

: +/ - 360 degrees

Reference system

: MS

Input resolution

: units

Active

: Every 100 ms

NC MD 564*, bit 3

Name

: Actual values division related

Significance

: The actual value is converted to an indexing position

(if the axis is an indexing axis).
Bit 3 = 0

: No conversion

Bit 3 = 1

: Conversion of actual value to indexing

position

Standard value

: Bit 3 = 0 (for all axes)

Active

: Every 100 ms

© Siemens AG 1992 All Rights Reserved 6FC5197- AA50