Siemens SINUMERIK 840C User Manual

Page 396

Advertising
background image

07.97

6 NC Machine Data (NC MD), NC Setting Data (NC SD)

6.10 MDs for flexible memory configuration

6.10

MDs for flexible memory configuration

Size of UMS memory

1)

60000

Default value

Lower input limit

Upper input limit

Units

256 KB

0

960 or 2 760 KB

2 760 KB (as from

SW 4.4)

4 KB/8 KB

Active

after SK

"Reconfigure

memory"

With the introduction of this MD it is no longer necessary to define the UMS size in the
configuration file in the MMC master control.

The upper input limit depends on the NCK memory capacity (4 or 8 MB memory).

Zero means no UMS (see functional description of "Flexible memory configuration").

Size of part program memory

1)

60001

Default value

Lower input limit

Upper input limit

Units

704 KB

8

960 or 2 760 KB

4 920 KB (as from

SW 4.4)

4 KB

Active

after SK

"Reconfigure

memory"

The upper input limit depends on the NCK memory capacity (4 or 8 MB memory).

Number of IKA points

1)

60002

Default value

Lower input limit

Upper input limit

Units

4 000

0
0

65 535

1 IKA point

Active

after SK

"Reconfigure

memory"

Zero means no IKA points.

Memory for drive software MSD

1)

60003

Default value

Lower input limit

Upper input limit

Units

0

0

1

Active

after SK

"Reconfigure

memory"

If an area of the memory is reserved for MSD drive software, 194 KB memory is occupied.

Zero means no memory.

The memory is only required for digital drives. The software only loads the MSD software if the
memory has been reserved for it.

Note:

The meaning of this machine data changes as from SW 6.
_______

1)

As from SW 4

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50