n

min

for n

act

< n

min

message motor 2

260

Default value

Lower input limit

Upper input limit

Units

12

0

Rated speed

rev/min

Active

at once

Input of response value for monitoring of the PLC status message n

act

< n

min

(see also

MD 241).

Creep speed pulse suppression motor 2

261

Default value

Lower input limit

Upper input limit

Units

Rated speed

––––––––––––––

256

0

Rated speed

rev/min

Active

at once

Input of response value for the internal n

min

sensor for stopping the drive with no reverse

rotation. When the speed n

min

is reached, the drive torque is cut off and the drive coasts to a

stop with any remaining kinetic energy.

Note:

This n

min

threshold is not the same as the response value of the n

min

monitor, but it may be

set to the same value.

n

x

for n

act.

< n

x

message motor 2

262

Default value

Lower input limit

Upper input limit

Units

6 000

0

Maximum motor

speed

rev/min

Active

at once

Input of response value for monitoring of the PLC status message n

act

< n

x

(see also

MD 241).

Tolerance band for n

set

= n

act

message motor 2

263

Default value

Lower input limit

Upper input limit

Units

20

0

Rated speed

––––––––––––––-1

16

rev/min

Active

at once

Input of response value for the tolerance band of the PLC status message n

set

> n

act

(see

also MD 241). The tolerance band of the n

set

= n

act

response threshold can be defined in

machine data MD 263.

Speed limitation motor 2

264

Default value

Lower input limit

Upper input limit

Units

Maximum motor

speed

0

Maximum motor

speed

rev/min

Active

at once

Input of maximum motor speed (n

max

) = speed safety limit.

©