Siemens SINUMERIK 840C User Manual

Page 588

Advertising
background image

09.95

7 Drive Machine Data (SIMODRIVE Drive MD)

7.4.3 Diagnosis/service MD (data description - as from SW 3)

Bit 10 - SW 4 Command variable

0 : torque
1 : speed

Bits 11-12

(Bit 11:) Master-slave operation setpoint

Bit 13

Travel against fixed stop setpoint

0 : off
1 : on

Bit 14

C axis mode setpoint

Bit 15

Sign of life

Status class 2

11006

Default value

Lower output limit

Upper output limit

Units

0000

FFFF

Hex

Active

after ramp-up

of 611D link

This machine data contains the warnings of a digital drive. It is stored on an axis-specific basis
at the interface between the SERVO and the 611D.

Bit 0

Bit 1 - SW 4

Bit 2 - SW 4

DC link (off ˆ

= DC link fault)

DC link voltage emergency retraction ( MD 1634)

Emergency retraction/generator mode active

0 : off
1 : on

Bit 3 - SW 4

Generator speed < minimum speed

0 : on
1 : off

Bits 4-13

Assigned to or reserved for internal system functions

Bit 14

Bit 15

Motor temperature warning

Heat sink temperature warning

0 : off
1 : on

Status class 3

11007

Default value

Lower output limit

Upper output limit

Units

0000

FFFF

Hex

Active

after ramp-up

of 611D link

This machine data contains the warnings of a digital drive. The machine data is stored on an
axis-specific basis at the interface between the SERVO and the 611D. For bits 6 to 15 there is
no evaluation or connection to the PLC.

Bit 0 - SW 3

Bit 0 - SW 4

Bit 1 - SW 3

Bit 1 - SW 4

Bit 2 - SW 3

Programmable message 1

Ramp-up completed

Programmable message 2

I M

d

I< M

dx

Programmable message 3

0 : off
1 : on

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

7–173

SINUMERIK 840C (IA)

Advertising
This manual is related to the following products: