Siemens SINUMERIK 840C User Manual

Page 198

Advertising
background image

12.93

6 NC Machine Data (NC MD), NC Setting Data (NC SD)

6.1.4 Breakdown of NC MDs/drive machine data

Number of TO parameters

13

Default value

Lower input limit

Upper input limit

Units

10

10

32

Active

see below

Normally, each tool offset has up to ten permanently allocated TO parameters. When required,
the user can upgrade the number of parameters to 32, and must allocate the added param-
eters (10 to 32) using the configuring terminal. The greater the number of TO parameters
allocated to a tool offset, the lower the number of tool offsets available to the user, as the
memory space available for tool offsets is limited.

Parameter

TO

Comments

10

204

409

Initial setting

11

186

372

12

170

341

13

157

315

14

146

292

15

136

273

16

128

256

17

120

240

18

113

227

19

107

215

20

102

204

21

97

195

22

93

186

23

89

178

24

85

170

25

81

163

26

78

157

27

75

151

28

73

146

29

70

141

30

68

136

31

66

132

32

64

128

(16 K tool memory)

Basic version with 8 K tool memory

Note carefully:

Modifications do not take effect until user memory has been formatted.

User memory is formatted in "Overall Reset" mode with either the "Format User Data" or the
"Format TO Data" softkey. For inform. on selecting "Overall Reset" mode, refer to Section
General Reset.

Number of D memories=

Memory configuration [BYTES]

Number of TO parameters *4

For SW 4 and higher see functional description "Flexible Memory Configuration".

©