7 Drive Machine Data (SIMODRIVE Drive MD)

12.93

7.1.2 MSD MD (data description - SW 3)

Rotor resistance cold motor 2

228

Default value

Lower input limit

Upper input limit

Units

Depends on motor

0

32 767

m

Active on

Power On

Input of rotor resistance (cold) as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 238).

Stator leakage reactance motor 2

229

Default value

Lower input limit

Upper input limit

Units

Depends on motor

0

32 767

m

Active on

Power On

Input of stator leakage reactance as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 238).

Rotor leakage reactance motor 2

230

Default value

Lower input limit

Upper input limit

Units

Depends on motor

0

32 767

m

Active on

Power On

Input of rotor leakage reactance as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 238).

Magnetizing reactance motor 2

231

Default value

Lower input limit

Upper input limit

Units

Depends on motor

0

65 535

m

Active on

Power On

Input of magnetizing reactance as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 238).

Upper speed X

h

characteristic motor 2

232

Default value

Lower input limit

Upper input limit

Units

Depends on motor

100

10 000

rev/min

Active on

Power On

Input of the upper speed limit for the X

h

characteristic (magnetizing reactance) as specified on

the motor data sheet (non-Siemens motor) or automatic parameterization using machine data
"Motor code number" (MD 238). In the field-weakening range, the magnetizing reactance X

h

increases linearly from the saturated value at the speed at which field weakening begins to the
unsaturated value at the upper limit speed of the X

h

characteristic (see diagram MD 175).

7–32

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

SINUMERIK 840C (IA)

Advertising
This manual is related to the following products: