Setting data for pcf files – Siemens SINUMERIK 840C User Manual

Page 127

Advertising
background image

09.95

Siemens AG 2001

All Rights Reserved

6FC5197–

j

AA50

4–64

SINUMERIK 840C (IA)

Setting data for PCF files:

You define the active PCF file in the general setting data.

The setting data are described in the Operator’s Guide.

DryĆrun feedrate

F

=

0

Incremental value for INC variable

INCĆvar.

=

50

Smoothing constant for thread cutting

T

= 0

PLC alarm text file

PCF 3

1)

16:38

JOG

PROGRAM RESET

BAG

:1

Kanal

:1

General data

Work area
limitation

General

data

Spindle

data

Scale

General
bits

Axial
bits

Cycle

data

MACHINE

PARAMETER PROGRAMM.

SERVICES DIAGNOSIS

Fig. 4.28

SW 1

Example

PCF file

N6000

(CLOSE DOOR) L

F

N6005

(LUBRICANT MIN REACHED!) L

F

N6010

(TOOL BREAK) LF

N6015

(HYDRAULIC OIL MIN REACHED) L

F

N6020

(OIL FILTER DIRTY) LF

N7000

(SWITCH ON MAIN DRIVE !!!) L

F

N8000

(DRIVE OF X AXIS DEFECTIVE) L

F

N9000

(SERVO ENABLE FOR Y AXIS MISSING) L

F

N9005

(FAN FAILURE !!!) L

F

N9010

(LOADER 1 DEFECTIVE) L

F

M30 L

F

SAVE

09:22

Start-up/Edit PLC data

Insert/

overwrite

Cut to

clipboard

Copy to

clipboard

Search

Paste from

clipboard

Undo

>>

PCF1

MACHINE

PARAMETER PROGRAMM.

SERVICES DIAGNOSIS

Fig. 4.29

ASCII editor with PCF 1 file

4 MMC Area Diagnosis

4.8.3 PCF files (up to SW 2)

1) Not in SW 1

Advertising