4 axis-specific md bits 1 (axial bits 1) – Siemens SINUMERIK 840C User Manual

Page 329

Advertising
background image

6 NC Machine Data (NC MD), NC Setting Data (NC SD)

08.96

6.6.4 Axis-specific MD bits 1 (axial bits 1)

6.6.4 Axis-specific MD bits 1 (axial bits 1)

7

6

5

4

3

2

1

0

Bit No.

NC MD

560*

Act.-value
display
modulo 360
deg.

Automatic
direction
recog. on
referencing

Software
limit
switches
active

NC start
although
ref. pt. not
reached

Rounding
for rotary
axes

Rounding to
whole/half
degrees

Dyn. SW
limit switch
for
following
axes

Servo loop
monitor not
active

Default value:

MD 5600-5629

0010 0000

Bit 7

For rotary axes (NC MD 564*, bits 5-1)! Acts on linear axes as well.

The actual-value display jumps from 359.999 to 0 degrees after one
revolution of the rotary axis.
Rotary axes, see also Section Functional Descriptions.

Active On:

RESET

Bit 6

Bit 6 =1

The NC can detect precisely the direction in which the reference point
lies from the "Deceleration" interface signal, as the reference point
extends up to the traversing limit (also see Section Axis (Analog) and
Spindle Installation).

Active On:

NC STOP

Traversing limit

Reference point cam

Operating point

Ref. point

Bit 6 = 0

If the axis is between the reference point cam and EMERGENCY STOP
when the control is powered up, the axis moves to EMERGENCY STOP
during reference point approach, as the control cannot detect from the
"Deceleration" interface signal whether the axis is ahead of or behind
the reference point cam (also see Section Axis (Analog) and Spindle
Installation).

Bit 5

Bit 5 = 0

The software limit switches defined in NC MD 224* to 236* are overrun
without a reaction of any kind. The working field limitation (setting data)
is not in force.
Active On:

RESET

6–144

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

SINUMERIK 840C (IA)

Advertising
This manual is related to the following products: